Autonomous research and development and design this small desktop product gas tight testing equipment, cooperated with many customers, and received unanimous praise and repurchase of customers. The structure is simplified, the test accuracy is high, which can meet the customer's high -speed productivity.
Equipment features
• Convenient structure, convenient and durable, high test accuracy, strong parts replacement, convenient after -sales and maintenance;
• It can adapt to a variety of product gas tests according to the product shape;
• Fast test time to meet customer shipments.
Equipment parameters
project | Specification | |
Differential pressure | Resolution | 0.1Pa |
Display range | ±999.9pa, (guaranteed accuracy range ±1000Pa) | |
precision | ±2.5% 3fdg: 1Pa, but below 50Pa is 2Pa | |
sensor pressure | SMPa | |
showShowonebit | test pressure | kPa, MPa (non-SI unit kg/cm2, PSL, bar, mmHg, etc. for foreign use) |
leakage | Pa , kPa, mL/s , mL/min , L/min, Pa-m3/s, E-3Pa-m3/s ,Pa/s ,Pa/min,*Pa/s , "Pa/min (non-sI unit mmH20, mmHg, inH20, etc.) | |
K(ve) | mL, L (non-SI unit for foreign use in3, ft3) | |
Leakage display | 4 bits, sampling frequency: 10 times/second | |
leak judgment value | ±999.9Pa or less | |
number of channels | 32ch(o~31) | |
time setting | 999.9 seconds (resolution 0.1 seconds) | |
power supply | Ac100-~240V soil 10%, 50/60Hz, 70VA3max | |
ambient temperature | s~45℃ | |
humidity | Below 80%RH, but no condensation. | |
weight | Controller about 2.6kg, air circuit device about 7.1kg | |
project | Specification | |
air source | Use clean air much higher than test pressure and drive pressure | |
Set driving pressure | Through the drive pressure on the instrument is set by the extinguisher pressure regulating valve; the setting range40o~70OkPa | |
Piping connection diameter | M1K1 | Special features limited to test product piping and standard product pipingl special connector |
M3K4 | Rc1/test pressure source, test product piping, standardproduct piping) | |
cpu | SH-2Aa44MHz, DRAM8MB | |
RS-232C(D-SUB9pin) | ID2 format | Output large-small leakage and limit values |
L2 format | Output L-DET-S-DET leak data | |
other | the other four | |
USB interface | data output | Judgment result, leakage value, measuring pressure, CH#.time etc. |
Setpoint output| | So the setting value of the setting screen | |
Standard accessories | Filter regulator for driving pressure, quick mounting bracket, 1O connector.Power cord, inspection report, operating instructions, quality tracking certificate | |